MPC Use Cases

MPC Dual Site

When MPC services are consumed at 2 locations, inter-site connectivity is provided by Equinix over multiple, shared 100 Gbps links.

This solution is suitable for disaster recovery or multi-site architecture at the application layer.

Currently only Layer 3 inter-site connectivity is available.

MPC Hybrid/Multicloud via Equinix Fabric

To connect the MPC environment to Equinix Fabric, a combination of services is needed. These include Equinix Fabric ports, MPC External networks, and Infrastructure Ports. Most providers connected to Equinix Fabric require routed (layer 3) based connection. To support Fabric connections to the MPC environment, BGP based routers are required in general. Equinix can provide this type of router via:

  • MPC Virtual Router

  • Managed Firewall

  • Managed Network Device

Equinix Fabric connections are offered in a redundant way. Therefore, 2 Fabric ports (primary and secondary), and 2 virtual connections (one per port) are required. Fabric connections themselves can be of type local or remote, depending on where the service provider is located. See Equinix Fabric to learn more.

The following table shows which Equinix services are needed for these use-cases.

MPC to Equinix Fabric

External Network Options MPC (DB3) to Equinix Fabric
Type of connectivity Dedicated connectivity
Included Equinix services 2x Cross-Connect

Additional required Equinix services

2x Equinix Fabric ports

≥ 2x MPC External networks

1x Infrastructure Port – redundant

≥ 2x Equinix Fabric Connections (local or remote)

Bandwidth 1 / 10 Gb
Remarks 2 Equinix Fabric connections per provider are needed. For each connection, one MPC External network is required.

Multi-site MPC to Equinix Fabric with Managed Firewall/Network

External Network Options MPC (DB3) to Equinix Fabric
Type of connectivity Dedicated connectivity
Included Equinix services 4x Cross-Connect

Additional required Equinix services

2x Equinix Fabric ports

2x Equinix Fabric Metro ports

≥ 8x MPC External networks

2x Infrastructure Port – redundant

≥ 2x Equinix Fabric Connection (local or remote)

Bandwidth 1 / 10 Gb
Remarks 2 Equinix Fabric connections per provider are needed. For each connection, one MPC External network is required.