更改虚拟设备资源大小
Network Edge用户可以将其虚拟设备资源更改为更大的资源大小,而无需删除现有设备并创建新设备。您可以保留相同的 IP 地址、配置和网络服务,例如虚拟连接和设备链路组 (DLG)。
功能支持
下表概述了支持的 VNF:
| Condition | Options |
|---|---|
| Deployment Type | Single, Redundant and Cluster deployment |
| Management Type | Self-Configured devices |
| Device Vendors | All vendor devices except Palo Alto Prisma SD-WAN device and Aviatrix (version 6.9) are supported |
| IBXs | Supported IBXs: AM7, AT4, CH3, DA11, DB3, DC21, FR2, HE7, HK4, LA4, LD7, MA5, MB2, MD2, ME2, MI1, ML5, MT1, MX2, NY5, OS3, PA3, SE4, SG4, SK1, SL1, SP3, SV15, SY5, TR2, TY9, VA1 |
不支持资源降级(将 VNF 大小更改为更小的核心数)。
- 不支持在以下 IBX(AM4、CH1、DA1、DC11、FR6、LD6、SG3、SV5、SY4)中配置的虚拟设备。
- 不支持 Equinix 配置的设备(已宣布销售终止、寿命终止)。
设备属性
该功能允许Network Edge基础架构根据请求的资源大小找到最佳计算。虚拟设备的以下属性与原始设备保持一致。
| Properties |
|---|
| Device UUID in the portal |
| Service ID |
| Image version |
| Device configuration |
| License |
| Serial number |
| Interface / MAC Address / VXLAN |
| Public IP (WAN Interface) |
| Access Control List |
| Device Link |
| Layer 2, Layer 3 virtual connections |
价格和账单变更
请注意,更改为更大的资源大小会改变虚拟设备的价格,并将适用所选资源大小的新价格。例如,如果原始期限从 1 月 1 日开始,期限为 12 个月(一年折扣),而您在同年 3 月 31 日更改了资源大小,则原始大小的价格将计费至 3 月 31 日。新资源大小的新定价将按比例计算。
服务中断
资源大小更改是一项受服务影响的功能。在更改大小之前,虚拟设备将重新启动。建议您在变更/维护窗口期间执行此资源变更,以减少服务中断。
升级单个设备的虚拟设备资源大小
要更改虚拟设备资源大小:
- 登录并打开Equinix客户门户:Fabric仪表盘。
- 从网络边缘菜单中,选择虚拟设备清单。请务必在继续操作之前切换到目标项目名称/ID。
- 找到要更改的虚拟设备,然后单击设备名称以查看虚拟设备详细信息页面。
- 在“设备详细信息”部分,点击“设备资源”旁边的“编辑”。
- 请从下拉菜单中选择更大规格的设备。您将看到网络边缘实例、许可证和额外带宽的新价格。
- 单击“查看并接受订单条款”。
- 滚动并阅读条款。在底部选择“我已阅读并理解这些条款”,然后点击“接受”。
- 点击保存更改。
您的设备状态将变为“设备资源升级进行中”。升级完成后,您的设备状态将变为“已配置”。
如果设备资源升级失败,则会在“设备详情”页面的“设备资源”部分显示失败消息。

资源变更流程失败时,系统会自动保留现有资源配置。您可以重试资源变更,或者提交支持案例以启动对此流程失败的调查。
服务影响
资源更改对服务影响的持续时间可能因虚拟设备类型而异。本节将讨论更改资源大小时的一些预期行为。
| Parameters / VNF Type | Expected Behavior |
|---|---|
| BGP Session | During resource size change, BGP session is expected to flap (for approximately 2 min) |
| Active SSH session | Any active SSH session will be disconnected |
| Traffic Loss | For all resource size change supported VNF, approximately 1~2 min of disruption is expected. It may change based on the BGP convergence time. Any VNF type specific behavior will be described below. |
| Check Point Firewall | Virtual devices reload is required after resizing |
| Fortinet FortiGate (Standalone, Redundant) | Auto-reboot is expected after resizing (traffic loss is up to 5 min) |
| Palo Alto VM-Series Firewall | Auto-reboot is expected after resizing (traffic loss is up to 8 min) |
| Palo Alto VM Cluster | Resizing start with Secondary node (Auto-reboot after resizing). Secondary node syncs up with Primary node (takes up to 10 min). Then Primary node resize takes place (auto-reboot after resizing) |
| Fortinet Cluster | Resizing start with Secondary node (Auto-reboot after resizing). Secondary node syncs up with Primary node (takes up to 10 min). Then Primary node resize takes place (auto-reboot after resizing) |
| Juniper vSRX Cluster | Resize of the Secondary node is first initiated, followed by Primary node resizing. |
冗余设备部署的升级资源大小
-
登录并打开Equinix客户门户:Fabric仪表盘。
-
从网络边缘菜单中,选择虚拟设备清单。请务必在继续操作之前切换到目标项目名称/ID。
-
找到要更改的虚拟设备,然后单击设备名称以查看虚拟设备详细信息页面。
-
在“设备详情”部分,点击“设备资源”。
-
请从下拉菜单中选择更高规格的设备。您将看到网络边缘实例、许可证和额外带宽的新价格。
-
单击“查看并接受订单条款”。
-
滚动并阅读条款。在底部选择“我已阅读并理解这些条款”,然后点击“接受”。
-
在“识别辅助设备”框中,选择辅助设备。

-
点击更新设备资源。
将开始升级辅助设备。辅助设备升级完成后,主设备资源调整开始。
您的设备状态将变为“设备资源升级进行中”。升级完成后,您的设备状态将变为“已配置”。
如果设备资源升级失败,则会在“设备详情”页面的“设备资源”部分显示失败消息。

升级群集设备部署的资源大小
更改资源大小的工作流程与冗余设备的工作流程类似。对于群集设备部署,两个设备的资源需要匹配。请注意,群集部署的辅助节点处于待机模式。调整大小过程首先从该辅助节点开始。一旦次节点的大小调整完成,主节点设备的大小也将随之调整。