跳至内容

更改虚拟设备资源大小

Network Edge用户可以将其虚拟设备资源更改为更大的资源大小,而无需删除现有设备并创建新设备。您可以保留相同的 IP 地址、配置和网络服务,例如虚拟连接和设备链路组 (DLG)。

功能支持

下表概述了支持的 VNF:

ConditionOptions
Deployment TypeSingle, Redundant and Cluster deployment
Management TypeSelf-Configured devices
Device VendorsAll vendor devices except Palo Alto Prisma SD-WAN device and Aviatrix (version 6.9) are supported
IBXsSupported IBXs: AM7, AT4, CH3, DA11, DB3, DC21, FR2, HE7, HK4, LA4, LD7, MA5, MB2, MD2, ME2, MI1, ML5, MT1, MX2, NY5, OS3, PA3, SE4, SG4, SK1, SL1, SP3, SV15, SY5, TR2, TY9, VA1
信息

不支持资源降级(将 VNF 大小更改为更小的核心数)。

  • 不支持在以下 IBX(AM4、CH1、DA1、DC11、FR6、LD6、SG3、SV5、SY4)中配置的虚拟设备。
  • 不支持 Equinix 配置的设备(已宣布销售终止、寿命终止)。

设备属性

该功能允许Network Edge基础架构根据请求的资源大小找到最佳计算。虚拟设备的以下属性与原始设备保持一致。

Properties
Device UUID in the portal
Service ID
Image version
Device configuration
License
Serial number
Interface / MAC Address / VXLAN
Public IP (WAN Interface)
Access Control List
Device Link
Layer 2, Layer 3 virtual connections

价格和账单变更

请注意,更改为更大的资源大小会改变虚拟设备的价格,并将适用所选资源大小的新价格。例如,如果原始期限从 1 月 1 日开始,期限为 12 个月(一年折扣),而您在同年 3 月 31 日更改了资源大小,则原始大小的价格将计费至 3 月 31 日。新资源大小的新定价将按比例计算。

服务中断

资源大小更改是一项受服务影响的功能。在更改大小之前,虚拟设备将重新启动。建议您在变更/维护窗口期间执行此资源变更,以减少服务中断。

升级单个设备的虚拟设备资源大小

要更改虚拟设备资源大小:

  1. 登录并打开Equinix客户门户:Fabric仪表盘
  2. 网络边缘菜单中,选择虚拟设备清单。请务必在继续操作之前切换到目标项目名称/ID
  3. 找到要更改的虚拟设备,然后单击设备名称以查看虚拟设备详细信息页面。
  4. 在“设备详细信息”部分,点击“设备资源”旁边的“编辑”。
  5. 请从下拉菜单中选择更大规格的设备。您将看到网络边缘实例许可证额外带宽的新价格。
  6. 单击“查看并接受订单条款”。
  7. 滚动并阅读条款。在底部选择“我已阅读并理解这些条款”,然后点击“接受”。
  8. 点击保存更改

您的设备状态将变为“设备资源升级进行中”。升级完成后,您的设备状态将变为“已配置”。

如果设备资源升级失败,则会在“设备详情”页面的“设备资源”部分显示失败消息。

注意

资源变更流程失败时,系统会自动保留现有资源配置。您可以重试资源变更,或者提交支持案例以启动对此流程失败的调查。

服务影响

资源更改对服务影响的持续时间可能因虚拟设备类型而异。本节将讨论更改资源大小时的一些预期行为。

Parameters / VNF TypeExpected Behavior
BGP SessionDuring resource size change, BGP session is expected to flap (for approximately 2 min)
Active SSH sessionAny active SSH session will be disconnected
Traffic LossFor all resource size change supported VNF, approximately 1~2 min of disruption is expected. It may change based on the BGP convergence time. Any VNF type specific behavior will be described below.
Check Point FirewallVirtual devices reload is required after resizing
Fortinet FortiGate (Standalone, Redundant)Auto-reboot is expected after resizing (traffic loss is up to 5 min)
Palo Alto VM-Series FirewallAuto-reboot is expected after resizing (traffic loss is up to 8 min)
Palo Alto VM ClusterResizing start with Secondary node (Auto-reboot after resizing). Secondary node syncs up with Primary node (takes up to 10 min). Then Primary node resize takes place (auto-reboot after resizing)
Fortinet ClusterResizing start with Secondary node (Auto-reboot after resizing). Secondary node syncs up with Primary node (takes up to 10 min). Then Primary node resize takes place (auto-reboot after resizing)
Juniper vSRX ClusterResize of the Secondary node is first initiated, followed by Primary node resizing.

冗余设备部署的升级资源大小

  1. 登录并打开Equinix客户门户:Fabric仪表盘

  2. 网络边缘菜单中,选择虚拟设备清单。请务必在继续操作之前切换到目标项目名称/ID

  3. 找到要更改的虚拟设备,然后单击设备名称以查看虚拟设备详细信息页面。

  4. 在“设备详情”部分,点击“设备资源”。

  5. 请从下拉菜单中选择更高规格的设备。您将看到网络边缘实例许可证额外带宽的新价格。

  6. 单击“查看并接受订单条款”。

  7. 滚动并阅读条款。在底部选择“我已阅读并理解这些条款”,然后点击“接受”。

  8. 在“识别辅助设备”框中,选择辅助设备。

  9. 点击更新设备资源

将开始升级辅助设备。辅助设备升级完成后,主设备资源调整开始。

您的设备状态将变为“设备资源升级进行中”。升级完成后,您的设备状态将变为“已配置”。

如果设备资源升级失败,则会在“设备详情”页面的“设备资源”部分显示失败消息。

升级群集设备部署的资源大小

更改资源大小的工作流程与冗余设备的工作流程类似。对于群集设备部署,两个设备的资源需要匹配。请注意,群集部署的辅助节点处于待机模式。调整大小过程首先从该辅助节点开始。一旦次节点的大小调整完成,主节点设备的大小也将随之调整。

此页面有帮助吗?