# Sustainability Tool The Sustainability Tool in the Customer Portal provides sustainability data dashboards and the ability to generate sustainability data reports. All users with organizational permissions can access the Sustainability Tool. The Sustainability Tool provides: * A dashboard view of customer-allocated Equinix Scope 1 emissions data (annual values). * A dashboard view of customer-allocated Equinix Scope 2 emissions data (monthly and annual values). * An interactive map of site-level sustainability initiatives. * A downloadable table of site-level sustainability initiatives and Power Usage Effectiveness (PUE). * Downloadable Green Power Reports and a dashboard view of the Green Power Report data. * Downloadable customer-allocated Equinix Scope 2 Estimate Reports providing estimated emissions and renewable energy data prior to annual verification. * Downloadable Customer Water Reports providing site Water Usage Effectiveness (WUE) and customer-allocated water metrics. Based on sustainability reporting best practices, Equinix obtains ISO 14064-3: 2019 Limited Assurance of our annual energy consumption, renewable energy consumption, and Scope 1, 2, and 3 greenhouse gas emissions, and water metrics. This verification process occurs in Q1 annually for the previous calendar year, and verified metrics become available in March. To access the Sustainability Tool: 1. Sign in to the [Customer Portal](https://portal.equinix.com/). 2. From the global navigation menu, click **Sustainability**. ![](https://docs.equinix.com/assets/images/sustainability-nav-07d4f037a3634a3484ae0e7ebbfd1a42.png) ## Overview[​](#overview "Direct link to Overview") The Overview Dashboard includes: * Annual Equinix Scope 1 emissions allocated to the customer associated with generators, natural gas, and refrigerants * Annual Equinix Scope 2 market-based and location-based emissions allocated to the customer; * Site-level, rolling 12-month Power Usage Effectiveness average. ![](https://docs.equinix.com/assets/images/sustainability-dashboard-488a9fbad0e4b8533cf8aefa5395b61d.png) For details on the methodology of calculated metrics, see [Sustainability Tool Methodology](https://docs.equinix.com/observability/sustainability/ecp-sustainability-gpreporting.md). ## Scope 2 Dashboard[​](#scope-2-dashboard "Direct link to Scope 2 Dashboard") Scope 2 Dashboard provides monthly and annual Equinix Scope 2 emissions data, including: * IT Electricity Usage – The total electricity consumed by your IT equipment. * Mechanical and Electrical (M\&E) Usage – The portion of site M\&E overhead attributed to your deployment. * Renewable Energy Coverage – The percentage of your electricity usage that is covered by renewables purchasing. * Renewable Energy Type – Contract details for renewables coverage at each IBX. * Location-Based Emissions – The emissions associated with your deployment, calculated based on the geographic location of each facility. * Market-Based Emissions – The emissions associated with your deployment, calculated based on the contractually purchased energy and renewable energy of each facility. * A monthly breakdown of electricity consumption and emissions. ## Map of Initiatives[​](#map-of-initiatives "Direct link to Map of Initiatives") The *Map of Initiatives* displays the sustainability initiatives at each Equinix IBX. * Click the map markers to view the sustainability details of the selected IBX. ![](https://docs.equinix.com/assets/images/map-of-initiatives-03f2f486472fdddbca3286b51231cdab.png) ### Your Sites[​](#your-sites "Direct link to Your Sites") The *Your Sites* table displays the sustainability initiatives and 12-month Power Usage Effectiveness (PUE12) data. To filter the data displayed in the table, use the Metro and date drop-down filters on the Overview Dashboard. To download the data in the *Your Sites* table in Excel format, click **Download Summary**. ### Glossary[​](#glossary "Direct link to Glossary") * A1A = American Society of Heating, Refrigerating and Air-Conditioning Engineers A1 Allowable * ATES = Aquifer Thermal Energy Storage * EC Plug Fan = Electrically Commutated Plug Fan * EV = Electric vehicle chargers * FCS = Free Cooling System * GoO = Guarantees of Origin * GR = Green roof * GW = Greywater used for cooling/irrigation * HCAC = Hot/Cold Aisle Containment * HVO = Hydrotreated Vegetable Oil * I-REC = International Renewable Energy Certificate * LED = LED lighting * LGC = Large-scale Generation Certificate * LGWPR = Low Global Warming Potential Refrigerants * REC = Renewable Energy Certificate * REGO = Renewable Energy Guarantees of Origin * RW = Rainwater Harvesting * Solar PV = Solar Photovoltaic * VPPA = Virtual Power Purchase Agreement `*` - Indicates reseller site `x` - Indicates xScale site ## Generating a Green Power Report[​](#generating-a-green-power-report "Direct link to Generating a Green Power Report") Green Power Reports can be downloaded as a PDF or Excel file and include the data found in the *Scope 2 Dashboard*, excluding the monthly breakdown of electricity consumption and emissions. * IT Electricity Usage – The total electricity consumed by your IT equipment. * Mechanical and Electrical (M\&E) Usage – The portion of site M\&E overhead attributed to your deployment. * Renewable Energy Coverage – The percentage of your electricity usage that is covered by renewables purchasing. * Renewable Energy Type – Contract details for renewables coverage at each IBX. * Location-Based Emissions – The emissions associated with your deployment, calculated based on the geographic location of each facility. * Market-Based Emissions – The emissions associated with your deployment, calculated based on the contractually purchased energy and renewable energy of each facility. To generate a report: 1. From the *Sustainability Tool*, select the *Reports* tab. Click **My Reports**. ![](https://docs.equinix.com/assets/images/sustainability-tool-reports-menu-01d9f17dad0b3f52bcd75ef2cf1c5ee9.png) 2. Click **Generate New Report** and select **Green Power Report**. 3. Select the date range, location, and billing account for your report. 4. Select whether you want the report in PDF or Excel format. You can enter a name for your report. ![](https://docs.equinix.com/assets/images/sustainability-report-generation-0aaa52133f861e66e7f8d5804f731d6f.png) 5. Click **Submit** to generate your Green Power Report. * A list of previously generated reports is available on the Reports tab. ## Global Reports[​](#global-reports "Direct link to Global Reports") Global Green Power Reports based on your billing account structure and 12-month Power Usage Effectiveness reports are still available upon request through your account team. Scope 1 data is not available at the global level. To get Scope 1 data across your global footprint, you need access to the Sustainability Tool in all your organizations. More information on global sustainability initiatives can be found on the [Equinix Corporate Sustainability](https://sustainability.equinix.com/) program page. ## Generating a Scope 2 Estimate Report[​](#generating-a-scope-2-estimate-report "Direct link to Generating a Scope 2 Estimate Report") Scope 2 Estimate Reports provide estimated, unverified electricity, renewables, and emissions data prior to the release of finalized, verified metrics. Reports can be downloaded as an Excel file and include estimated Green Power Report metrics, excluding Renewable Energy Type. * IT Electricity Usage – The total electricity consumed by your IT equipment (calculated using the same methodology as the Green Power Report). * Estimated Mechanical and Electrical (M\&E) Usage – The estimated portion of site M\&E overhead attributed to your deployment. * Estimated Renewable Energy Coverage – The estimated percentage of your electricity usage that is covered by renewables purchasing. * Estimated Location-Based Emissions – The estimated emissions associated with your deployment, calculated based on the geographic location of each facility. * Estimated Market-Based Emissions – The estimated emissions associated with your deployment, calculated based on the contractually purchased energy and renewable energy of each facility. To generate a report: 1. From the *Sustainability Tool*, select the *Reports* tab. Click **My Reports**. 2. Click **Generate New Report** and select **Scope 2 Estimate Report**. 3. Select the date range, location, and billing account for your report. * You will only be able to select dates for which the data has not yet been third-party verified. Verification occurs annually from January through April for the previous calendar year. 4. Enter a name for your generated file. 5. Click **Submit** to generate your Scope 2 Estimate Report. A list of previously generated reports is available on the Reports tab. > **Note** > > The values in Scope 2 Estimate Reports are calculated estimates and are subject to change following Equinix’s annual greenhouse gas inventory and third-party data verification. Estimated Power Usage Effectiveness (PUE), renewable energy coverage, and emissions factors from the previous reporting year are used where current-year verified values are not yet available. Sites that opened during the reporting year covered in the Scope 2 Estimate Report are excluded due to incomplete data availability. Use of this information for formal reporting or regulatory disclosures is at the customer’s discretion. See [report methodology](https://docs.equinix.com/observability/sustainability/ecp-sustainability-gpreporting.md) for more information. ## Generating a Customer Water Report[​](#generating-a-customer-water-report "Direct link to Generating a Customer Water Report") Customer Water Reports (CWRs) provide customers with water metrics associated with their Equinix deployments at sites that use water for cooling. CWRs include the following metrics: * Customer-allocated water withdrawal * Customer-allocated water discharge * Customer-allocated water consumption * Site-level Water Usage Effectiveness (WUE) To generate a report: 1. From the Sustainability Tool, select the Reports tab. Click **My Reports**. 2. Click **Generate New Report** and select **Customer Water Report**. 3. Select the date range, location, and billing accounts for your report. 4. Enter a name for your generated file. 5. Click **Submit** to generate your CWR. > **Note** > > Site-level WUE and customer-allocated water metrics are available only for sites that utilize water for cooling. Sites that do not use water for cooling are excluded from Customer Water Reports. ## Publishing Policy[​](#publishing-policy "Direct link to Publishing Policy") You may extract the information contained within the dashboards and downloadable reports for your sustainability and environmental reporting, but the reports themselves are confidential and should not be made publicly available.