# Ordering Cross Connects Without an LOA You can submit orders for new Cross Connects without a Letter of Authorization (LOA). You will need to have the relevant information about both the A-side **and** the Z-side of the connection. Customers can order Cross Connects without a signed quote. Service orders and quotes are typically used only for first installs of new customers, or when a customer purchases Cross Connects that deviate from list and customer-specific pricing. Customers can also to order Cross Connects by contacting the Equinix Global Service Desk (GSD) by email or by phone (email orders result in higher accuracy). GSD orders are processed manually, which results in a longer delay before the order is booked. In addition, a GSD agent might need to contact the customer for missing information or to clarify requirements. > **Note** > > To order Cross Connects in the Customer Portal and API, you must have Cross Connect and Intra-Facility Cables ordering permission. ## Steps to Place an Order[​](#steps-to-place-an-order "Direct link to Steps to Place an Order") 1. Sign in to the [Customer Portal](https://portal.equinix.com/). 2. From the *Orders and Tickets* menu, choose **Cross Connect**. ![Orders and Tickets menu with Cross Connects highlighted](https://docs.equinix.com/assets/images/xc-orders-cc-d35a5813039bfe279a4c60ca511f58b4.png) 3. Click the Cross Connect card in the Interconnection Catalog. ![Interconnection Catalog with the Cross Connect card](https://docs.equinix.com/assets/images/xc-orders-unified-cc-73b10b37c48b3255373bbf85ce2e9ca5.png) 4. Review the information about the *Unified Cross Connect Ordering Experience* and click **Next**. 5. In the Select LOA section, click **Order Without LOA**. ![Select LOA page with Order Without LOA selected](https://docs.equinix.com/assets/images/xc-orders-no-loa-d8b800d012da53c4430cdbaf9281425c.png) > **Note** > > A blue progress bar is displayed across the top of the page. Mouse over the bar to view a drop-down list that shows your progress in the ordering process. Completed sections are displayed with check marks. Click a completed section to return and make changes. > > ![Order Cross Connect progress menu](https://docs.equinix.com/assets/images/xc-orders-progress-5f059c4c1469588ac5ae33bf7ca19a9c.png) ## Choosing a Z-side Provider[​](#choosing-a-z-side-provider "Direct link to Choosing a Z-side Provider") By default, the Connect to a Provider tile is selected. Select a Z-side Provider from the list. You can filter the list by entering a provider or an IBX data center. Click **Next**. ## Configuring the Connection[​](#configuring-the-connection "Direct link to Configuring the Connection") The choices in the following forms are based on the assets that are assigned to your organization and account. The values that are displayed are the ones that are available for your situation. Below the summary in the Connection Overview diagram, choose an *A-side IBX* and a *Z-side IBX* from the drop-down lists. ![Configure your Cross Connect page with the A-side list open](https://docs.equinix.com/assets/images/xc-order-aside-dropdown-136f7a3d887ab94ceeb57c7a5ed38c9e.png) If your new connection can be paired with a primary Campus Cross Connect, a message is displayed below the Connection Overview diagram. This means that the connection can serve as a diverse campus Cross Connect backup if a cable failure occurs. The [Configuring Redundancy](#configuring-redundancy-optional) section below describes how to set up this feature. ![Configure your Cross Connect page with a Campus Cross Connect note](https://docs.equinix.com/assets/images/xc-diverse-campus-note-d2a6bf03e5f680ef6326f7ef7f849832.png) ### Configuring the A-side[​](#configuring-the-a-side "Direct link to Configuring the A-side") In the Connection Details section, click **+ Add Connection** for the A-side connection. ![Connection Details with the Add Connection button](https://docs.equinix.com/assets/images/xc-orders-connections-no-loa-24b7d4382b9c2f25355e28f65f5c4c27.png) The Asset Connection Details form is displayed on the right side of the page. For *Connection 1*, enter a patch panel, or provide the following details: ![Asset Selection Details panel for the A-side](https://docs.equinix.com/assets/images/xc-order-conn1-aside-c91d4689f0d0ffbe32b9c49a2f9e438d.png) 1. Choose a Cage, a Cabinet, a Patch Panel, a Connection Service, and a Media Type from the drop-down lists. 2. Choose an optional Protocol Type and a Connector Type from the drop-down lists. 3. Choose Port A and optional Port B from the drop-down lists, or from the Visual Patch Panel display of available ports below. The Next Available port is the default. 4. To request that Equinix install the new Cross Connect from the panel to your equipment, select Patch my equipment and choose the Device Cabinet, Connector Type, and Port. Additional Smart Hands fees will apply. 5. Select Add Cross Connect Light Link Verification. An additional charge for each connection will apply. 6. Click > Z-side Details to expand the right-side form. ### Configuring the Z-side[​](#configuring-the-z-side "Direct link to Configuring the Z-side") For *Connection 1*, enter a patch panel, or provide the following details: ![Asset Selection Details panel for the Z-side](https://docs.equinix.com/assets/images/xc-order-conn1-zside-d8605959f6bbf8f0a80d1fdf4235ad25.png) 1. Choose a Cage, a Cabinet, a Patch Panel, and a Connector Type from the drop-down lists. By default, the Connection Service and Media Type are set from the A-side values. 2. Choose Port A and optional Port B from the drop-down lists, or from the Visual Patch Panel display of available ports below. The Next Available port is the default. 3. Enter a Circuit ID. ### Configuring Redundancy (optional)[​](#configuring-redundancy-optional "Direct link to Configuring Redundancy (optional)") To add a diverse connection for more redundancy, select *Create Diverse Campus Cross Connect*. ![Diverse Campus Cross Connect options](https://docs.equinix.com/assets/images/xc-order-diverse-campus-bcf5714f0b304639f4701c221ff62d48.png) Select a connection type: * Pair with Existing Primary Asset – Choose an available Asset from the drop-down list. * Create Primary and Diverse Pair – Provide A-side Details and Z-side Details for the new connection. 1. Choose a Cabinet, Patch Panel, Connection Service, Media Type, optional Protocol Type, and Connector Type from the drop-down lists as described in the steps above. 2. Choose Port A and optional Port B from the drop-down lists, or from the Visual Patch Panel display of available ports below. The Next Available port is the default. To add more primary connections, click **Save** and **Add Next**. Repeat the previous steps for all the additional A-side and Z-side connections. When all the connection details are complete, click **Save and Close** in the lower right corner. ## Review the Connection Details[​](#review-the-connection-details "Direct link to Review the Connection Details") The updated A-side and Z-side Connection Details are displayed. If applicable, the diversified connections are displayed too. Review the updated list in the *Connection Details* section. * To make changes, click the pencil on the right side of a connection row. Edit the information in the *Asset Selection Details* form and click **Confirm Selection**. * To delete a connection, click the trash can on the right side of a connection. Click **Delete Connection**. At least one connection must be present to complete the order. To view all the details and charges, click **Show Order Summary**. This information updates as you progress through the ordering process. ## Schedule Your Order[​](#schedule-your-order "Direct link to Schedule Your Order") Choose to either schedule your order to match circuit enablement OR to match completed installation. ### To Match Circuit Enablement[​](#to-match-circuit-enablement "Direct link to To Match Circuit Enablement") 1. To place your order on hold to match the date that your circuit is enabled, select *Circuit Delivery Date* and choose a date from the calendar. This is the date when your carrier commits to enabling the circuit. After your carrier delivers the service, Equinix completes the installation. 2. Enter or upload additional details and instructions that might help the Equinix technician. 3. When all the order details are correct, click **Next**. ### To Match Completed Installation[​](#to-match-completed-installation "Direct link to To Match Completed Installation") To schedule the date for your completed installation, select a date in the calendar view. You can select from a date range suggested by Equinix. Or, you can request a different date based on your schedule and pricing needs. ![Installation date calendar](https://docs.equinix.com/assets/images/xc-order-calendar-a0c266b203ced246a88b18abdf398dd4.png) Select one of these calendar options: * Flexible (F) – Your order is completed on a date that Equinix recommends, and you receive a discount on your installation charge. * Standard (S) – Your order is completed during a typical, guaranteed installation interval. * Expedited (E) – Your order is completed more quickly. Click a date in the calendar, and choose a time from the drop-down list. Approval is required, and additional fees might apply. Click **Next**. ## Provide Contact Information[​](#provide-contact-information "Direct link to Provide Contact Information") In the A-side Contacts List, you are automatically assigned as the technical contact and the notification contact. To add additional contacts, either: * Click the *Search for a contact* field, begin typing a name, and select the name from the filtered drop-down list. ![Provide Contact Information page](https://docs.equinix.com/assets/images/xc-orders-diloa-a-contacts-f657f8aff6a94eb3fd6718df540bfef4.png) * Click *Add from Directory* to search the Contact Directory list. Select one or more contacts, and click **Done** in the lower right corner. If the contact you want to add is not included in these lists, click **Add New Contact**. Complete the *Add an Unlisted Contact* form and click **Add** in the lower right corner. The contacts that you add are automatically assigned as a Notification Contact to receive order updates. You can select one of them as a Technical Contact. In the Z-side Contacts List section, select *Notify Z-side contact upon completion*. Enter the contact email address. Click **Next**. ## Review and Submit Your Order[​](#review-and-submit-your-order "Direct link to Review and Submit Your Order") After you have reviewed the information for this new Cross Connects connection, you can make final changes and complete the ordering process. 1. In the Review Order form, verify that the Connection Details, Additional Details, and Contact Information sections are correct. 2. Enter additional Customer Reference information. 3. In the Terms and Conditions section, click **Review Terms and Conditions**. 4. Review the *Acceptance* section and click **Accept**. ![Terms and Conditions window](https://docs.equinix.com/assets/images/xc-orders-diloa-terms-b813ba5da3ae81c54fed7849965e2869.png) 5. Click **I Accept** and **Submit**. The *Order Submitted* confirmation window displays your order number. ![Order Submitted confirmation](https://docs.equinix.com/assets/images/xc-order-success-options-3acf4a9a4aa2711315e9ce361d7933d8.png) To find details about the status of your order, click **Track in Order History**. After your order is completed, you’ll receive a **survey email** inviting you to provide feedback on your experience. This survey allows you to comment on how the order was fulfilled and whether you were satisfied with the work performed.